SRY7 Straight Rod Electric Heating Rod

SRY2 and SRY3 types are used for oil in open or closed oil tanks. SRY4 type is used for flowing or circulating oil.

Specifications and Technical Data
1. Specifications and Dimensions: See table and figure

Model FL2 Voltage
(V)
Power
(kW)
Dimensions and Installation Dimensions (mm) Weight
(kg)
A B Immersion Length in Oil C
SRY2-220/1 220 1 307 230 " 1.45
SRY2-220/2 220 2 507 430 " 1.90
SRY2-220/3 220 3 707 630 " 2.35
SRY2-220/4 220 4 922 845 " 2.83
SRY3-220/1 220 1 625 375 570 0.77
SRY3-220/2 220 2 825 575 770 1.01
SRY3-220/3 220 3 925 675 870 1.13
SRY3-220/4 220 4 1125 875 1070 1.37
SRY4-220/5 220 5 697 620 " 2.45
SRY4-220/6 220 6 807 730 " 2.70
SRY4-220/8 220 8 1007 930 "  


 : The mounting hole for SRY2 and SRY4 types is Ø72 mm

2. Working voltage tolerance: not greater than 1.1 times the rated value, the shell should be effectively grounded.
3. Working environment: relative humidity not greater than 95, no explosive or corrosive gases.
4. Metal tube material: No. 10 steel.
5. Maximum working temperature: SRY2, SRY3 is 300, SRY4 is 100.
6. Working pressure for SRY2 and SRY4 types is less than 2 kg/cm².
7. Fastener length for SRY3 type is 25 mm.
III. Usage, Maintenance, and Precautions
1. Dimension "B" in the outline drawing must be fully immersed in oil to avoid burning the element. The heated oil should be non-corrosive.
2. For SRY3 type, the working liquid level must be below the fastener and above the dimension line "B".
3. When melting solid oils such as asphalt and paraffin, reduce the voltage during use, and then increase to the rated voltage after melting to prevent heat concentration and reduce element life.
4. If carbon deposits are found on the tube surface, they must be removed before reuse to avoid reduced efficiency or even burning of the element.
5. The element should be stored in a dry place. If the insulation resistance drops below 1 megohm due to long-term storage, it can be dried in an oven at about 200°C for several hours (or apply low voltage to the element for several hours) to restore insulation resistance.