Heating cable is mainly used for living heating, plant cultivation, pipe insulation, etc. Heating cable uses single or multiple alloy heating wires as heat source, high-purity, high-temperature, electrically fused crystalline magnesium oxide as thermal conductive insulation, seamless continuous stainless steel or copper tube as sheath, manufactured by special process. For places with strong corrosion, PE or low-smoke halogen-free jacket can be added. Heating cables with maximum temperature below 250°C comply with IEC800 (92) standard, "Rated voltage 300/500V heating cables for living facilities heating and anti-icing"; those above 250°C comply with enterprise standards.

Electrical Performance


Resistance tolerance: ±10%
Dielectric performance — Heating cable withstand voltage: 1200VAC/1min
Insulation resistance — Finished product test: 100MΩ/500VDC
Sheath continuity — Test insulation resistance after immersing the entire heating cable (including joints) in water for 12 hours.

Precautions


During transportation, storage, installation and use, avoid repeated rolling, bending, twisting, especially do not impact the heating cable. Both ends of the heating cable must not be immersed in water or exposed to rain. One end of the heating cable is connected to power supply, the other end's conductive core must not be short-circuited, must not contact conductive materials, and should be sealed firmly.

Basic Parameters

 
Model Size
Width×Thickness (mm)
Conductor Structure Strands×Wires×Diameter (mm) Output Power W/m at 10°C Start Current A/m at 10°C Max Surface Temperature °C Max Withstand Temperature °C Min Installation Temperature °C Working Voltage (V)
TL-7 7.5×3.5 2×7/0.32 20 0.6 65±5 105 -40 220
TL-9 9.0×3.5 2×7/0.32 20 0.6 65±5 105 -40 220
TL-10 11.0×3.6 2×9/0.32 20, 25 0.6-0.8 65±5 105 -40 220




Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.
 
WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Tel: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us