Dali Electric recommends
Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on 1988-07-20, implemented on 1989-07-01
Note: 1. The electric heater parameters listed in this table are applicable to bolts with a center hole diameter of d=22.6±0.2mm. For electric heaters that do not conform to the center hole diameter and specification parameters listed in this table, the user and the manufacturer shall negotiate.
2. The surface power density of the electric heaters listed in this table is selected as 8-11W/cm².
II. Technical Requirements
(1) The turbine bolt electric heater shall meet the following requirements:
1. The raw materials used for the electric heater shall meet the following requirements:
① The composition of the insulating material magnesium oxide shall comply with HG3-1294-80 "Magnesium Oxide";
② Magnesium oxide must be dried before use;
③ The heating material used for the electric heater is 0Cr27A17Mo2 high-resistance electric heating alloy wire, with an operating temperature of 400°C, and technical requirements according to GB1234 "High-Resistance Electric Heating Alloy";
④ The protective tube material for the electric heater is 1Cr18Ni9Ti heat-resistant stainless steel tube. Its technical requirements shall comply with YB804 "Stainless and Acid-Resistant Steel Seamless Tubes". Use of other materials shall be agreed upon between the manufacturer and the user;
⑤ The inside of the protective tube for the electric heater shall be deburred, then cleaned with gasoline or kerosene, and dried before use.
2. The finished electric heater shall meet the following requirements:
① The rated working voltage of the electric heater is 220±20V. DC 100V, low voltage 50V;
② For electric heaters with an insertion length within 1m, the straightness of the centerline shall not exceed φ0.3mm; for insertion lengths between 1-2m, the straightness of the centerline shall not exceed φ0.4mm;
③ The diameter deviation of the insertion part is -0.20mm/-0.50mm;
④ The length deviation of the insertion part is ±5mm, the heating length deviation is ±5mm, and the bottom cold end length is 25-30mm;
⑤ The electric heater shall heat evenly during use, and local overheating is not allowed.
(2) During the life test of the electric heater, each heating time is 10-20min. Under intermittent heating conditions, with a total gap between the bolt center hole and the outer diameter of the electric heater of 0.8-1.3mm, the cumulative life shall not be less than 50h.
(3) The connection between the alloy resistance wire and the lead wire shall be firm and reliable, without looseness. The shell must be properly grounded.
(4) After the steel tube of the electric heater is cold-drawn and reduced, the surface shall be inspected by dye penetrant testing or with a magnifying glass of 5x or more, and there shall be no cracks or other defects. The tube reduction shall be formed in one direction.
(5) The cold end seal of the electric heater shall be tightly sealed to prevent moisture ingress and insulation damage.
(6) After the electric heater is manufactured, after one and a half months, its insulation resistance shall be measured at room temperature with a 500V megohmmeter (can be performed at the manufacturer or user site) and shall not be less than 50MΩ.
III. Test Methods and Acceptance Rules
After each electric heater is assembled, its insulation resistance shall be measured at room temperature with a 500V megohmmeter and shall not be less than 50MΩ. It shall also withstand a 1500V withstand voltage test for 1 minute without breakdown or flashover. Then, in air, it shall be powered on and heated at the rated working voltage for 2-3 minutes without overheating, and the insulation resistance shall not be less than 0.5MΩ, and the leakage current shall not exceed 0.5mA per kilowatt. Its power shall also be checked to see if it meets the order requirements (deviation ±5%). After the test, check whether all parts of the electric heater are intact.
Each electric heater shall be inspected and approved by the manufacturer's quality inspection department and accompanied by a certificate of conformity before shipment.
LD-6-9-12 Type AC/DC Adjustable Bolt Heating Rod Control Cabinet
The distribution cabinet is a special device specifically configured for bolt heating rods, and there are two types: AC and DC distribution cabinets. The DC cabinet uses a silicon-controlled three-phase full-wave circuit, with smooth DC output waveform. The silicon-controlled trigger part is made using advanced integrated circuit trigger principles, allowing different heating voltages to be selected according to different situations, facilitating the disassembly and assembly of cylinder bolts.
Input power: AC 50Hz, three-phase four-wire 380V
Output current: DC ripple frequency 6fo-180V stepless adjustment
Output DC: 12 branches, each independently controlled by a single switch, with a maximum output power of 15KW per branch.

Note: The above information and technical parameters are compiled and released by Yangzhou Dali Electric Co., Ltd.