①? The rated working voltage of the electric heater is 220±20V. DC 100V, low voltage 50V;
②? For electric heaters with insertion length within 1m, the straightness of the centerline shall not exceed 0.3mm; for insertion length between 1-2m, the straightness of the centerline shall not exceed 0.4mm;
③? The diameter deviation of the inserted part is -0.20mm/-0.50mm;
④? The length deviation of the inserted part is ±5mm, the heating length deviation is ±5mm, and the cold end length at the bottom is 25-30mm;
⑤? The electric heater must heat evenly during use, and local overheating is not allowed.
2. Test Methods and Acceptance Rules
After each steam turbine bolt heating rod is assembled, its insulation resistance shall be measured with a 500V megohmmeter at room temperature and shall not be less than 50MΩ. It shall withstand a 1500V withstand voltage test for 1 minute without breakdown or flashover. Then, in air, it shall be heated by electricity at the rated working voltage for 2-3 minutes without overheating, and the insulation resistance shall not be less than 0.5MΩ, and the leakage current shall not exceed 0.5mA per kilowatt. And check whether its power meets the order requirements (deviation ±5%). After the test, check whether all parts of the electric heater are intact.
HuiCongNet manufacturer Baoying County Ruipu Electrical Equipment Factory provides you with detailed product prices, product pictures and other product introduction information for direct supply of steam turbine bolt heating rods. You can directly contact the manufacturer to obtain specific information about direct supply of steam turbine bolt heating rods. Please indicate that you saw it on HuiCongNet.