Sheath-type Tubular Electric Heater

Keywords:Electric heater factory direct sales,Sheath-type electric heater, Sheath-type tubular electric heater

Main technical parameters, specifications, length:
Rated voltage: Single phase 220V, Three phase 380V
Working medium: Mineral oil and water and other media with good heat dissipation effect
Surface heating power: 1KW-4KW 1.5w/cm2, 5KW-8KW 2.5 w/cm2
Working pressure: 0.6Mpa

HRY14 tubular electric heater is improved on the basis of SRY2 ordinary tubular electric heater, with improved wiring device and heating structure. It uses three heating tubes as a group, effectively reducing the surface load of the heater, and can directly replace SRY2-SRY4 type heaters.

Sheath-type Electric Heater Instructions:
1. The working voltage must not exceed 1.1 times its rated value, and the shell should be effectively grounded.
2. The dimension "B" in the figure must be fully immersed in oil (and checked regularly) to avoid burning. The heated oil should be free of corrosive gases.
3. The mounting hole size of the tubular electric heater is φ65mm.
4. This model of tubular electric heater is designed according to JB2379-78 flowing oil standard, with surface load of 2-3.8 w/cm2.
5. When selecting, the heater size should be determined according to the actual size of the heating medium.
Note: The tubular electric heater can be directly mixed with SRY2 and SRY4 types.